称重传感器

称重传感器
称重传感器

产品类别

联系方式

电话:0755-26738591

传真:0755-26998440

网址:http://www.octsources.com

邮箱:sales@octsources.com

地址:深圳市南山区南头街道虹步路39号马家龙14栋大习科创大厦

产品类别 > 隔离器/转换器 > VTU-006B电压隔离器

VTU-006B电压隔离器

所属品牌:美国 OSI 来源:深圳市现代豪方仪器仪表点击:280次发布时间:2021-09-28

VTU-006B电压隔离器


品牌:美国 OSI

型号:VTU

类型:单向直流电压隔离器

 



特征/FEATURES

•输出与输入电隔离,并与输入成正比

•仅单向信号

•提供1500V电介质保护

•Output is electrically isolated from the input and is directly proportional to the input.

•Unidirectional signals only.

•Provides 1500V dielectric protection.

 


应用/APPLICATIONS

•监测变电站或电路性能

•分路输出的隔离和放大

•发电机或太阳能电场监测

• Monitoring of substation or electric circuit performance.

• Isolation and amplifi cation of shunt output.

• Electric generator or solar fi eld monitoring.







参数

电压输入

0-1000Vdc

输出

0-5Vdc、0-1mAdc、4-20mAdc

准确性

±0.25% 读数

频率

DC-1000Hz

测量

直流电

系统配置

1Ø

 

 

 

 

输入

直流电压

标准输出型号VTU

0-1mAdc

4-20mAdc

0-5Vdc

0-0.05

015B

015E

015X5

0-0.10

016B

016E

016X5

0-10

001B

001E

001X5

0-25

002B

002E

002X5

0-50

003B

003E

003X5

0-100

004B

004E

004X5

0-150

005B

005E

005X5

0-250

006B

006E

006X5

0-300

007B

007E

007X5

0-400

008B

008E

008X5

0-500

009B

009E

009X5

0-600

010B

010E

010X5

0-700

011B

011E

011X5

0-800

012B

012E

012X5

0-900

013B

013E

013X5

0-1000

014B

014E

014X5

 

注:700-1000V型号配有外部分压器箱.50mV和100mV型号可用于并联隔离.









规格

输入INPUT

电压

0-1000Vdc

频率范围

直流至1000Hz

负重

0.05和0.10mV输入型号

>500Ω

所有其他型号

>100kΩ

超载

0.05-600V

2 X F.S.或最大850Vdc

700-1000V(带外部分隔盒)

最大1500Vdc

介电测试DIELECTRIC TEST

直接输入/输出/外壳

1500Vac

仪表功率INSTRUMENT POWER

标准

115Vac±15%,50/60Hz,4VA

“-22”选项

230Vac±15%,50/60Hz,4VA

输出OUTPUT

响应(至90%)

500μs

加载

“B”型号

(0-1mAdc输出)

0-5

“E”型号

(4-20mAdc输出)

0-300Ω

“X5”型号

(0-5Vdc输出)

≥2kΩ

现场可调校准

±10%

精确ACCURACY(±0.25%Rdg.,±0.1%F.S.@DC包括线性和重复性的影响)

温度TEMPERATURE

温度效应

(-5至+40

±1.0%Rdg.,±0.1%F.S.































安装/操作/保修/INSTALLATION / OPERATION / WARRANTY

 

 

 

安装说明/INSTALLATION INSTRUCTIONS

1.只能由合格的电工进行安装!

2.在进行任何电气连接之前,确保电气服务已断开。

3.支路保护按国家和地方规范要求设置检查机构的报告。

4.按要求布线,并按照本表和装置上的接线图固定到端子上。

5.传感器适合安装在600Vac线路上。

6.为防止与带电电路接触,当安装在裸母线上时,要求传感器安装在需要使用工具进入的外壳中。当安装在绝缘电缆上时不需要第二个外壳的电缆。

1. Installation should be performed by qualifi ed electricians only!

2. Make sure electrical service is disconnected before making any electrical connections.

3. Branch circuit protection is required to be provided in accordance with the National and Local codes of the inspection authority.

4. Route wires as required and secure to terminals per connection diagram on this sheet and on the unit.

5. Transducers are suitable for installation on 600Vac lines.

6. To prevent contact with live circuits, when installed on a bare bus bar, the transducer is required to be mounted in an enclosure that requires the use of a tool for access. When installed on an insulated cable this second enclosure is not required.

 

 

操作说明/OPERATING INSTRUCTIONS

1.本装置适用于海拔2000米以下的室内使用。

2.根据安装类别(过电压)II,污染等级2的瞬态过电压。

3.如果需要清洁外表面,则应断电所有供应服务(两个测量和仪表电源电路),并用软刷刷洗或用低压空气吹扫。使用适当的眼部保护。不适合清洗软管。

4.最高相对湿度80%,温度最高31ºC,线性下降至50% 40℃时的相对湿度。

5.最大工作温度范围为-20°C至60°C。

1. This unit is intended for indoor use at altitudes up to 2000 meters.

2. Transient overvoltages according to Installation Category (overvoltage) II, Pollution Degree 2.

3. If cleaning of the exterior surface is necessary, de-energize all services of supply (both measuring and instrument power circuits) and brush with a soft brush or blow off with low-pressure air. Use appropriate eye protection. Not suitable for hose-down cleaning.

4. Maximum relative humidity 80 percent for temperatures up to 31ºC decreasing linearly to 50 percent relative humidity at 40ºC.

5. Maximum operating temperature range is -20°C to 60°C.

 