称重传感器

称重传感器
称重传感器

产品类别

联系方式

电话:0755-26738591

传真:0755-26998440

网址:http://www.octsources.com

邮箱:sales@octsources.com

地址:深圳市南山区南头街道虹步路39号马家龙14栋大习科创大厦

产品类别 > 隔离器/转换器 > SCT-300E2电流传感器

SCT-300E2电流传感器

所属品牌:美国 OSI 来源:深圳市现代豪方仪器仪表点击:436次发布时间:2021-08-06

SCT-300E2电流传感器


品牌:美国 OSI

 

型号:SCT

 

类型:分芯交流电流传感器

 

交流输入/直流输出

 


简单介绍

SCT是一个与电流传感器集成的分芯电流互感器,可提供高达500Aac的电流测量范围。可提供0-1mAdc、0-5Vdc或环路供电的4-20mAdc输出。输出与输入的平均绝对值成比例,并经过校准以表示正弦波的RMS值。

The SCT is a split-core current transformer integrated with a current transducer to provide current measurement ranges up to 500Aac. Outputs of 0-1mAdc, 0-5Vdc, or loop-powered 4-20mAdc are available.The output is proportional to the average absolute value of the input and is calibrated to represent the RMS value of a sine wave.



特点/FEATURES

·对极性不敏感

·分芯设计,便于安装

·在50-400Hz范围内准确可靠

·Insensitive to polarity

·Split-core design for easy installation

·Accurate and reliable from 50-400Hz

 


应用/APPLICATIONS

·专为应用而设计

·需要精确的电流测量

· Designed for applications

·requiring accurate current measurements






参数

电流输入

0-500Aac

输出

0-5Vdc、0-1mAdc、4-20mAdc道路

准确性

±0.5% FS

频率

50-400Hz

测量

交流电

核心类型

分裂核心

系统配置

 

 

 

 

型号选择

输入交

流电流

标准输出SCT

0-1mAdc*

4-20mAdc*

0-5Vdc*

0-50

050A

050E2

050CX5

0-100

100A

100E2

100CX5

0-200

200A

200E2

200CX5

0-300

300A

300E2

300CX5

0-400

400A

400E2

400CX5

0-500

500A

500E2

500CX5

 

*模型由测量线自供电。

**4-20mA回路供电型号需要15-40Vdc电源

* models are self-powered from measured line.

** 4-20mA loop-powered models require 15-40Vdc supply









规格

输入/INPUT

电流范围/Current

0-500Aac

频率范围/Frequency Range  

50-400Hz

负重/Burden

0.5 VA最大

电流过载/Current Overload

5倍额定值10秒/小时

介电试验/DIELECTRIC TEST

输入/输出量/ Input/Output/Case

1800Vac

仪表电源/INSTRUMENT POWER

“A”、“CX5”型号

自供电

“E2”型号

15-40Vdc

输出/OUTPUT

响应/Response

(to 90%)

<300m装载

“A”型

0-1mA型号

 0-10kΩ

“CX5”型号

0-5Vdc models

>100

“E2”型号

4-20mA型号

0-500Ω

精确/ACCURACY

25C,60Hz

±0.5%F.S.

所有条件

±0.7%F.S.

输出纹波

<0.5%F.S.

温度和物理/TEMPERATURE & PHYSICAL

温度范围/Temperature Range

-20℃~+60℃

重量/Net Weight

1.0 lb

 

 

 

 



尺寸连接





















安装/操作/保修/INSTALLATION / OPERATION / WARRANTY

 

安装说明/INSTALLATION INSTRUCTIONS

1.只能由合格的电工进行安装!

2.在进行任何电气连接之前,确保电气服务已断开。

3.支路保护按国家和地方规范要求设置检查机构的报告。

4.按要求布线,并按照本表和装置上的接线图固定到端子上。

5.传感器适合安装在600Vac线路上。

6.为防止与带电电路接触,当安装在裸母线上时,要求传感器安装在需要使用工具进入的外壳中。当安装在绝缘电缆上时不需要第二个外壳的电缆。

1. Installation should be performed by qualifi ed electricians only!

2. Make sure electrical service is disconnected before making any electrical connections.

3. Branch circuit protection is required to be provided in accordance with the National and Local codes of the inspection authority.

4. Route wires as required and secure to terminals per connection diagram on this sheet and on the unit.

5. Transducers are suitable for installation on 600Vac lines.

6. To prevent contact with live circuits, when installed on a bare bus bar, the transducer is required to be mounted in an enclosure that requires the use of a tool for access. When installed on an insulated cable this second enclosure is not required.

 

 

操作说明/OPERATING INSTRUCTIONS

1.本装置适用于海拔2000米以下的室内使用。

2.根据安装类别(过电压)II,污染等级2的瞬态过电压。

3.如果需要清洁外表面,则应断电所有供应服务(两个测量和仪表电源电路),并用软刷刷洗或用低压空气吹扫。使用适当的眼部保护。不适合清洗软管。

4.最高相对湿度80%,温度最高31ºC,线性下降至50% 40℃时的相对湿度。

5.最大工作温度范围为-20°C至60°C。

1. This unit is intended for indoor use at altitudes up to 2000 meters.

2. Transient overvoltages according to Installation Category (overvoltage) II, Pollution Degree 2.

3. If cleaning of the exterior surface is necessary, de-energize all services of supply (both measuring and instrument power circuits) and brush with a soft brush or blow off with low-pressure air. Use appropriate eye protection. Not suitable for hose-down cleaning.

4. Maximum relative humidity 80 percent for temperatures up to 31ºC decreasing linearly to 50 percent relative humidity at 40ºC.

5. Maximum operating temperature range is -20°C to 60°C.








浏览了该产品的用户还浏览: