产品描述/DESCRIPTION

DVTH是一个隔离的高压直流传感器,具有与满标度(F.S.)成比例的输出。包装是一个紧凑、易于安装的DIN导轨安装外壳。

The DVTH is an isolated high-voltage dc transducer with a proportional Zero to Full-Scale (F.S.) output. Packaging is a compact, easy-to-install, DIN rail-mount enclosure.

 



特征/FEATURES

•高压直流测量

•各种输出类型

•输入、输出和仪表电源电气隔离

•宽交流/直流仪表电源范围

•DIN导轨安装外壳

• High-Voltage dc measurement

• Variety of output types

• Input, output and instrument power are electrically isolated

• Wide ac/dc instrument power range

• DIN rail-mount enclosure



应用/APPLICATIONS

•分路隔离

•太阳能(PV)串监测

•数据中心UPS电池监控

•公用事业蓄电池监测

• Shunt isolation

• Solar (PV) String monitoring

• Data Center UPS Battery monitoring

• Utility Storage Battery monitoring






参数

电压输入

0-1500Vdc

输出

0-5Vdc、0-10Vdc、0-1mAdc、4-20mAdc、4-12-20mAdc

准确性

±0.25% FS

测量

直流电

系统配置

1Ø

 

 


 

型号

输出

极性选择

DVTH-1500B

0-±1mAdc

双向

DVTH-1500D

0-±10Vdc

双向

DVTH-1500E

4-20mAdc

单向

DVTH-1500EM

4/12/20mAdc

双向

DVTH-1500X5

0-±5Vdc

双向









规格

输入INPUT

电压范围

0-±1500Vdc

超出范围(无损坏)

0-±1800Vdc

阻抗

≥1.5MΩ

频率

直流电

输出OUTPUT

缩放比例

0至F.S.输入=0至F.S.输出

加载

 5V, 10V

≥2KΩ

4-20mA,4/12/20mA

0-500Ω

1mA

0-10KΩ

响应(10% 至90%)

100μs

仪表功率INSTRUMENT POWER

9-28V,dc/50-400Hz,≤3W

精度(设定点、线性、偏移)

±0.25% F.S.

介电测试DIELECTRIC TEST

输入到输出/仪表电源

4000Vdc

仪表输出功率

500Vdc

温度与环境TEMPERATURE & ENVIRONMENTAL

温度工作范围

-40°C至+85°C

影响

(-30至+60

±0.005%/

(-40至+85

±0.008%/

相对湿度

0-95%,不冷凝

物理性能PHYSICAL

(根据EN50052/EN60715,安装在标准35mm“顶帽”导轨上)

终端线尺寸

12-30AWG

防护等级

IP20

重量

0.35 lbs








尺寸图


















连接图

















安装/操作/保修/INSTALLATION / OPERATION / WARRANTY

 

 

 

安装说明/INSTALLATION INSTRUCTIONS

1.只能由合格的电工进行安装!

2.在进行任何电气连接之前,确保电气服务已断开。

3.支路保护按国家和地方规范要求设置检查机构的报告。

4.按要求布线,并按照本表和装置上的接线图固定到端子上。

5.传感器适合安装在600Vac线路上。

6.为防止与带电电路接触,当安装在裸母线上时,要求传感器安装在需要使用工具进入的外壳中。当安装在绝缘电缆上时不需要第二个外壳的电缆。

1. Installation should be performed by qualifi ed electricians only!

2. Make sure electrical service is disconnected before making any electrical connections.

3. Branch circuit protection is required to be provided in accordance with the National and Local codes of the inspection authority.

4. Route wires as required and secure to terminals per connection diagram on this sheet and on the unit.

5. Transducers are suitable for installation on 600Vac lines.

6. To prevent contact with live circuits, when installed on a bare bus bar, the transducer is required to be mounted in an enclosure that requires the use of a tool for access. When installed on an insulated cable this second enclosure is not required.

 

 

操作说明/OPERATING INSTRUCTIONS

1.本装置适用于海拔2000米以下的室内使用。

2.根据安装类别(过电压)II,污染等级2的瞬态过电压。

3.如果需要清洁外表面,则应断电所有供应服务(两个测量和仪表电源电路),并用软刷刷洗或用低压空气吹扫。使用适当的眼部保护。不适合清洗软管。

4.最高相对湿度80%,温度最高31ºC,线性下降至50% 40℃时的相对湿度。

5.最大工作温度范围为-20°C至60°C。

1. This unit is intended for indoor use at altitudes up to 2000 meters.

2. Transient overvoltages according to Installation Category (overvoltage) II, Pollution Degree 2.

3. If cleaning of the exterior surface is necessary, de-energize all services of supply (both measuring and instrument power circuits) and brush with a soft brush or blow off with low-pressure air. Use appropriate eye protection. Not suitable for hose-down cleaning.

4. Maximum relative humidity 80 percent for temperatures up to 31ºC decreasing linearly to 50 percent relative humidity at 40ºC.

5. Maximum operating temperature range is -20°C to 60°C.