称重传感器

称重传感器
称重传感器

产品类别

联系方式

电话:0755-26738591

传真:0755-26998440

网址:http://www.octsources.com

邮箱:sales@octsources.com

地址:深圳市南山区南头街道虹步路39号马家龙14栋大习科创大厦

产品类别 > 隔离器/转换器 > CTU-0400电流传感器

CTU-0400电流传感器

所属品牌:美国 OSI 来源:深圳市现代豪方仪器仪表点击:474次发布时间:2021-09-09

CTU-0400电流传感器


品牌:美国 OSI

 

型号:CTU

 

类型:直流电流传感器

 



产品描述DESCRIPTION

CTU系列是一种开环霍尔效应电流传感器。霍尔效应传感器检测导体中电流产生的磁场强度和方向。适当的信号调节提供与测量电流的振幅和方向成比例的输出。

紧凑型分芯封装提供了在新应用或Retrofit应用中易于安装的特点。

The model CTU-XXXXZ is an open-loop Hall-effect current transducer. Hall-effect sensors detect the strength and direction of the magnetic fl ux created by current fl owing in a conductor. Appropriate signal conditioning provides an output proportional to both the amplitude and direction of the measured current.

Ease of installation in either new or retrofi t applications is provided by the compact split-core packaging.






电流输入

0-2000Aac

输出

0-±5Vdc、4-20mAdc、0-±10Vdc、0-±1mAdc、4-12-20mAdc

准确性

±1.0% FS

核心类型

分裂核心

频率

直流电

测量

直流电

 

    



型号

输入直流范围

CTU-0025

±0-25Adc

CTU-0050

±0-50Adc

CTU-0100

±0-100Adc

CTU-0150

±0-150Adc

CTU-0200

±0-200Adc

CTU-0300

±0-300Adc

CTU-0400

±0-400Adc

CTU-0500

±0-400Adc

CTU-0600

±0-600Adc

CTU-0800

±0-800Adc

CTU-1000

±0-1000Adc

CTU-1500

±0-1500Adc

CTU-2000

±0-2000Adc

 

 



Z

输出类型

B

0-±1mAdc

Z

0-±10Vdc

X5

0-±5Vdc

E

4-20mAdc

EM

4/12/20mAdc









规格参数

 

输入INPUT

电流范围

0-2000Aac

超出范围(无损坏)

>5kA max.

介电测试DIELECTRIC TEST

输入窗口

2200Vac

仪器输出功率

600Vac

仪表功率INSTRUMENT POWER

电压

12Vdc,±5%

-24选项

24Vdc,±5%

电流

≤100mAdc

温度TEMPERATURE

工作范围

-40ºC to +85ºC

温度效应

±0.025%/ºC

输出OUTPUT

载入

型号B

0-10kΩ

 

型号D & X5

≥2kΩ

 

型号E & EM

0-300Ω

响应时间(90%)

5毫秒典型值

精确ACCURACY

设定值、线性和重复性

±0.5% F.S.

0025Z的设定值

 ±1.0% F.S.

零偏移

(超出范围10倍后)

±0.04% F.S.

(-1000, -1500, -2000)

<±0.4% F.S.

物理性能PHYSICAL

工作湿度

0-95%不冷凝

重量(包括电缆)

≤0.75lb.

终端

配备8英尺4芯22AWG可拆卸电缆






































安装/操作/保修/INSTALLATION / OPERATION / WARRANTY

 

安装说明/INSTALLATION INSTRUCTIONS

1.只能由合格的电工进行安装!

2.在进行任何电气连接之前,确保电气服务已断开。

3.支路保护按国家和地方规范要求设置检查机构的报告。

4.按要求布线,并按照本表和装置上的接线图固定到端子上。

5.传感器适合安装在600Vac线路上。

6.为防止与带电电路接触,当安装在裸母线上时,要求传感器安装在需要使用工具进入的外壳中。当安装在绝缘电缆上时不需要第二个外壳的电缆。

1. Installation should be performed by qualifi ed electricians only!

2. Make sure electrical service is disconnected before making any electrical connections.

3. Branch circuit protection is required to be provided in accordance with the National and Local codes of the inspection authority.

4. Route wires as required and secure to terminals per connection diagram on this sheet and on the unit.

5. Transducers are suitable for installation on 600Vac lines.

6. To prevent contact with live circuits, when installed on a bare bus bar, the transducer is required to be mounted in an enclosure that requires the use of a tool for access. When installed on an insulated cable this second enclosure is not required.

 

 



操作说明/OPERATING INSTRUCTIONS

1.本装置适用于海拔2000米以下的室内使用。

2.根据安装类别(过电压)II,污染等级2的瞬态过电压。

3.如果需要清洁外表面,则应断电所有供应服务(两个测量和仪表电源电路),并用软刷刷洗或用低压空气吹扫。使用适当的眼部保护。不适合清洗软管。

4.最高相对湿度80%,温度最高31ºC,线性下降至50% 40℃时的相对湿度。

5.最大工作温度范围为-20°C至60°C。

1. This unit is intended for indoor use at altitudes up to 2000 meters.

2. Transient overvoltages according to Installation Category (overvoltage) II, Pollution Degree 2.

3. If cleaning of the exterior surface is necessary, de-energize all services of supply (both measuring and instrument power circuits) and brush with a soft brush or blow off with low-pressure air. Use appropriate eye protection. Not suitable for hose-down cleaning.

4. Maximum relative humidity 80 percent for temperatures up to 31ºC decreasing linearly to 50 percent relative humidity at 40ºC.

5. Maximum operating temperature range is -20°C to 60°C.




浏览了该产品的用户还浏览:

3ACT-001A电流传感器

3ACT-005A换能器

3ACT-010A传感器

3ACT-020A电流传感器

3ACT-025A换能器

称重传感器客服
客服头部
称重传感器
称重传感器

扫一扫加微信公众号